RoadRunners BRR-L Programming guide May 2006
© Baracoda 2006 12/29
Power = 20dBm (*)
2.8.2 Sniff settings
The higher the Sniff period, the higher is the latency and the smaller is the power consumption.
Default value is 150ms.
Sniff period = 150ms (*)
\VT\VT^\NUL\ENQ\HT\NUL\FNC4 \NUL\FNC4p\FF\FF
sniff period = 150ms
Sniff period = 100ms
\VT\VT^\NUL\ENQ\HT\NUL\FNC4 \NUL\FNC4 \FF\FF
sniff period = 100ms
Sniff period = 200ms
\VT\VT^\NUL\ENQ\HT\NUL\FNC4 \SOH@\FF\FF
sniff period = 200ms
Sniff period = 500ms
\VT\VT^\NUL\ENQ\HT\NUL\FNC4 \ETX \FF\FF
sniff period = 500ms
Sniff period = 300ms
\VT\VT^\NUL\ENQ\HT\NUL\FNC4 \SOH\FNC4a\FF\FF
Set sniff period = 300ms
2.8.3 Power emission settings
You can configure your scanner to work at 20 dBm (default setting) or 10 dBm.
Due to local laws, you may not use 20 dBm in some countries
Power = 10dBm
\VT\VT^\NUL\ENQ;\NUL\VT\NUL\VT\FF\FF
Set 10 dBm
2.8.4 Security (code PIN) settings
Some BT device will not accept connections with devices that do not have a security code.
Disable BT security code
\VT\VT^\NUL\STX!\NUL\FF\FF
Disable BT Security Mode
Enable BT security code (*)
\VT\VT^\NUL\STX!\SOH\FF\FF
Enable BT Security Mode
\VT\VT^\NUL\ENQ;\NUL\DC4\NUL\DC4\FF\FF
power = 20 dBm